Li-po Balancer & Charge Guard
The ¡°Balancer & Guard¡± is fully featured and PULG & PLAY connection to Li-ploy pack and works with any type of Li-polymer charger. It is also specially designed with an advanced accurate micro-computer chip that scans each cell¡¯s condition and determines what the pack is needed for the best reconditioning. If one or more cells are charged over 4.35 V, while charging, the Balancer-Guard will cut off input charge circuitry and balance to prevent accidentally expose while charging Li-polymer batteries. The Balancer Guard bypasses charge current any cell(s) are over charged or imbalanced. It is truly associated with balancer and safety charge guard system for the best safety for Li-poly battery. Please read carefully to correct use.
l Easy connection 2-4 cells in series pack
l Operating with any Li-polymer charger
l Automatically bypass charge current if any cell over charged or imbalanced.
l Individual cell LED display while bypass charge
l Full balanced charge LED display(it can be monitor charger condition)
l Operating form 2S to 4S Li-poly packs
l Over charge warning LED display
l Over charge protection circuitry
l Error Connection warning.
l Input power: 18V max
l Charge control current 6Amps(0.0065 OHM)
l Bypass Current::300mA Max/ cell
l Cell configuration: Auto cell detect in series. (Compatible ¡°PolyQuest¡± or others with pigtail adapter)
l Balance control type: Active and shunt automatically control
l Overcharge protection voltage: 4.35V +/- 0.01V
l Protection release voltage: imbalance voltage lower than +/- 0.02V
l Imbalance control: 0.01V
l Full indicator: 4.18V/cell and imbalance 0.01V
A: How to use with charger:
1. Connect Li-poly pack to the Balancer-Guard
a. 2S or 3 S: Use 2S or 3S pigtail adapter as shown picture
b. 4S: Connect 5PIN connector to the Balancer-Guard
c. Error LED begins flash if incorrect matching connector used.
2. Wait for 2-3seconds then, verify number of ON ¡°CELL LED(s)¡± with pack.
3. Connect input wire to charger (RED[+],Black[-])
4. Start charge.
5. Cells in a pack should be balanced when the charge is completed: (¡°FULL¡± LED should be solid ON if all cells are fully charged over 4.18V and balancing is completed.(This LED could be slowly ON/OFF at the edge of full level)
6. Wait until all connected ¡°CELL LEDs¡± are turned off to last minute balancing (it is not necessary every charge cycle).
7. Remove 5PIN connector from Li-poly Pack
B: **When flash ¡°ERORR LED¡± while charging (Over charge cut-off)**
It is a warning message that charge is safely disconnected from charger caused by one or more cells are reached to 4.35V (It is possibility happens that the pack is extremely imbalanced or incorrect charge settings),
Simply do following steps to reconditioning and balancing pack.
1. STOP charge or Remove input wire from charger.
2. Wait until all connected ¡°CELL LED(s)¡± are turned off.
3. Remove 5 pin connector form Li-poly pack and Plug-in again
4. Connect input wire to charger(make sure check charge settings are correct)
5. Start charge (0.1A -0.5A charge current recommended according to pack capacity).
1. Do not make a short circuitry input or output wires.
2. Use dry and cool environment
3. Do not use a unattended
4. Do not modify any wire configuration in a pigtail; adaptors.
5. Always keep clean connectors and carefully handle all the connectors.
6. Remove Balancer/Guard connector form Li-poly pack after fully balanced pack.
D: ERROR LED troubleshooting
1. ¡°ERROR¡± LED fast Flash while plug-in pack: check number of cell in a pack or matching pigtail adaptor
2. ¡°ERROR¡± LED fast Flash while charging: Over charge cut off is activated. (Follow above [B] to reconditioning pack)
Red LED is "FULL" LED. |
If you got a solid Red LED, it means all cells are fully charged |
and balancing is completed. |